The SpectraMax® 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications, especially DNA analysis. The patented multichannel optical design of the SpectraMax® 190 Absorbance Microplate Reader mimics a dual beam spectrophotometer, measures each sample in the plate. In luminescence mode, if you are specifying a wavelength for the read, you can select an emission bandwidth of either 15 nm or 25 nm. Molecular Dynamics Phosphorimager Model 425F + details. Wavelength Selection . -Narrow bandwidths deliver increased measurement accuracy and linearity - Wavelength Range: 190 - 1000 nmSpectraMax 190: SpectraMax 340PC384: SpectraMax Plus384: VERSAmax: Vmax: Tecan: Sunrise: Trinean: DropSense96: AMBIENT TEMPERATURE STORAGE: Liconic: LPX 220 Hotel: LPX 440 Hotel: Thermo Fisher Scientific: Cytomat 10 Hotel: Cytomat 2 Hotel: Cytomat 24 Hotel: Cytomat 8 Linear Hotel: Cytomat 9 Hotel (MPH) BAR CODE. SpectraMax 190 Absorbance Microplate Reader by Molecular Devices®. With the ability to detect DNA down to 25 ng per well, as well as a limit of calculation to 75 ng per well, the SPECTRAmax 190 microplate spectrophotometer gives you the. Also review the Maintenance and Troubleshooting chapter of the user guide for your model plate reader. This user guide provides detailed instructions on how to operate, maintain, and troubleshoot the device, as well as examples of applications and. A wide linear dynamic range ensures accurate assay results across a broad span of sample types. spr * SpectraMax ABS Plus SpectraTest ABS2 v1. SpectraMax® M3, M4, M5, and M5e Multi-Mode Microplate Readers User Guide 0112-0115 F July 2010 M3-M5e_manual. United States. If values are present, then. In manufacturing DNA/RNA-synthesizers for universities, hospitals and private companies all over the world, the group relies on the SpectraMax 190 Absorbance Microplate Reader. no. 312 gain calibration failed. The PathCheck sensor can extend the instrument linearity by a factor of three or more. Ends from. Microplate Spectrophotometer Operator’s Manual. For more sample throughput, the system can0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. SPECTRAmax PLUS 384 Microplate Spectrophotometer Operator’s Manual vii Conventions Used in this Manual The names of keys that appear on the SPECTRAmax PLUS 384 control panel are shown in boxed Helvetica type. 3™ software instructions View of back of Spectra Max 190 . Perform the following steps to install the drivers: Start > Control Panel > System. Fresh por cine aortic valve cusps were supplied by St. for every assay. Accurate quantitation The optical design of the SpectraMax 340PC384 reader truly mimics a dual. Example: [Drawer]. 1) This. 5 - 2. Table 1. Perkin Elmer HTS 7000 Bio Assay ReaderExplore how the SpectraMax i3 Multi-Mode Platform provides an unlimited breadth of application possibilities, and how it can evolve with your future needs. The SpectraMax 190 reader is the tool for DNA analysis. Brand: Molecular. The solution was diluted with distilled water until the absorbance reached 0. To provide access to disconnect power from the instrument, maintain a 20 cm to 30 cm (7. The SpectraMax 190 has a multichannel design for 96-wellSpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Capable of detecting DNA down to 25 ng per well, this model gives users the same sensitivity as conventional systems to produce accurate nucleic acid measurements. 0112-0115J 9 Chapter1:Introduction TheSpectraMax®M3Multi-ModeMicroplateReader,SpectraMax®M4Multi-ModeMicroplate Reader,SpectraMax®M5Multi-ModeMicroplateReader,andSpectraMax®M5eMulti-ModeWhat is the part number for the filter wheel motor? I am looking to replace mine because I suspect it is the cause of the failureProducts : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, SpectraMax Plus 384 reader, SpectraMax 190 reader, VersaMax reader, FlexStation 3 reader I need to reinstall the USB driver for my plate reader. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid- Tecan Infinite M200 PRO Plate Reader-Tecan Mono Absorbance, Tecan Luminescence, Tecan PMT Enhanced -used system- includes Tecan system dongle. Manufacturer: Molecular Devices; Model: SpectraMax 190; The SpectraMax® 190 Absorbance Microplate Reader is the ideal equipment for many life science applications including DNA analysis. Devices® SPECTRAmax 190 microplate reader at a wavelength of 600 nm. The instrument is designed to regulate the temperature of the plate chamber from 5°C above ambient to 45°C. For colony-forming assays, stable Caki-1 and 796-O anti-miR-155/TCL6-OE cells and their respective control cells were plated at a low density onto 10-cm dishes (1,000. Order Now. SpectraMax iD3 and iD5 Register or Sign In. In this application note, we demonstrate the measurement of luciferase expression in CHO-K1 cells using the SpectraMax Glo Steady-Luc Reporter Assay Kit, which affords long-lasting luminescence signals. • Trained in running Qbit real-time assay, 6 plex. Absorption was measured at 450 nm 24 h after premix added using SpectraMax 190 (Molecular Devices, LLC, Sunnyvale, CA, USA) to produce a cell. If no values are present, the water constant values are missing from the NVRAM. SPECTRAmax® 190. Cet appareil ISM est confomre à la norme NMB-001 du Canada. UV-Star ® 96W Microplate, well working volume 25-370 μL; total well volume 392 μL. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. 2 nm * Wavelength Range 190 – 850 nm * Photometric. 0200-6263. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner robots. . ; India imports most of its Spectramax from United States, China and Austria and is the largest importer of Spectramax in the World. For more information, please visit us at would like to show you a description here but the site won’t allow us. Perkin Elmer 1420 Victor 3V + details. Add to cart. SpectraMax® Plus 384 provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. Photometric accuracy. Short measurement times, 80 seconds for a 1536-well plate, and any plate format up to 1536 wells for flexibility. SpectraMax® 190 absorbance plate reader enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. 303 unable to cal dark current. This location is in Saanich. Lease/finance or buy Molecular Devices SpectraMax 190 Microplate Reader. For very concentrated samples, use aMolecular Devices Spectramax 190 Plate Reader used. Step 3. You can also contact Technical Support by email. Bioz Stars score: 86/100, based on 1 PubMed citations. Features: Absorbance, Fluorescence and Luminescence plate reader for all microplate formats. , Sunnyvale, CA, USA) depending on the substrate. Not all manufacturers microplates are the same with regard to. • Responsible for quality control assay on biological fluids and protein concentrations performed on SpectrMax 190 Microplate Reader. The SpectraMax® 340PC384 Reader from Molecular Devices provides everything needed to measure absorbance in the visible range, including temperature control, a robotics-compatible interface and SoftMax® Pro Data Acquisition and Analysis Software. S. 波长范围 190-1000 nm 调节步进 1 nm 波长带宽 2 nm 波长精确度 ± 1 nm 波长重复性 ± 0. Examples: “Press carefully to engage,” “ Do not. 306 plate air cal. SpectraMax 190 Absorbance Microplate Reader from Molecular Devices LLC. Molecular Devices Spectramax 190 Plate Reader used. 83% (w/v) FeCl 3 ⋅6H 2 O, and samples were incubated at room temperature for 25 min. Exceptional performance SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. Perkin Elmer 1420 Victor 3V + details. 7°C and the bottom to 36. United States. 0200-7027. Temperature control and shaking come as standard. Since this is an older reader, we recommend that new users choose our newer model i3 reader. Next, the supernatant was discarded, 120 μL of DMSO was added to each well, and the plate was shaken for 10 min in the dark to sufficiently dissolve the formazan crystals. After establishing a stable baseline, reactions were started by the addition of 1 µM La-dependent MDH purified as described before ( 41 ). Week starts on: Sunday Monday. Check: In the data table create two new columns and add the following formulas: !Pathchecklm900. The UV-vis. The patented multichannel optical design of the SpectraMax® 190 Absorbance Microplate Reader mimics a dual beam spectrophotometer, measures each sample in the plate directly, and eliminates measurement error due to variations in light output between. Turn on the Spectra MAX 190 spectrophotometer using the switch located next to the plug in the back on the right hand side (as you face the spec). EXPERIENCED-We have been building labs, equipping labs, and supplying lab equipment parts and service for over 20 years. 009-QG. Add to cart. It features a dual-monochromator system, a large dynamic range, and a high-throughput capability. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. Microplate spectrophotometer (54 pages) Measuring Instruments Molecular Devices FlexStation II Operator's Manual. SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual 1-3 Introduction General Overview The SPECTRAmaxŽ 190 microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. 316 grating motor driver faulty. Description 1. The PathCheck sensor can extend the instrument linearity by a factor of three or more. When the correct COM port is selected, the. Manufacturer: Molecular Devices; Model: SpectraMax 190 * Wavelength Selection Monochromator, tunable 1. Compatible with Molecular Devices SPECTRAmax 190 and 250 plate readers. 단일 튜브 디스펜싱에서 전체 96 및 384 well 플레이트세척까지 간소화된 Microplate 세척입니다. SpectraDrop Micro-Volume Refills, 24-Well Bottom Slides. The Molecular Devices SpectraMax 384 Plus is a UV/Vis spectrophotometer and microplate reader combination for more reliable and fast data reporting with built-in cuvette port and microplate drawer. The SpectraMax® absorbance spectrophotometers and plate readers provide the versatility and convenience for a wide range of assays such as ELISAs, nucleic acid and protein quantitation, and microbial growth. The SpectraMax M2 and M2e systems provide the multi detection microplate readers with dualmonochromators, dual-mode cuvette ports, with top & bottom reading. A SOFTMAX® PRO SOFTWARE Version 5 for Mac® and Windows® User Guide Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part #0112-0140 Rev. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. The SpectraMax ® Plus 384 Microplate Reader gives you walk-up convenience for both standard spectrophotometer and microplate reader applications on the same instrument. SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. The SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. 8 in. SpectraMax® Plus 384 microplate reader can run both standard spectrophotometer and microplate reader applications on the same instrument. Our Price: $10,995. Every step is optimized for data acquired from a Molecular Devices microplate reader or data imported from. Molecular Devices SpectraMax 190 Temperature range: 4°C above ambient to 45°C Digital controller and display Sold as-is The Molecular Devices SpectraMax 190 can be used to quantify DNA and perform endpoint, kinetic, and spectral scanning analyses. Molecular Devices SpectraMax ABS Plus Microplate Reader. The SpectraMax 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications,. item 3 Molecular Devices SpectraMax 190 Microplate Spectrophotometer Molecular Devices SpectraMax 190 Microplate Spectrophotometer . Ultraviolet transparent multiwell plates from Greiner; Highly recommended for measurements of DNA and protein concentrations at 260 nm or 280 nm, respectively; No need for expensive and fragile quartz glass plates; UV transparent to 200 nm;We used three technical replications for each biological replication and measured absorbance at 595 nm using a SpectraMax 190 spectrophotometer (Molecular Devices, LLC, Sunnyvale, CA). Información para pedidos: Includes current version of SoftMax Pro Software. 3. Wavelength precision. Rigging/Removals Loading, Rigging, and Freight are at buyers expense. 304 signal level saturation. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. ATP concentration (M) Average RLU SpectraMax L SpectraMax i3x (cartridge) SpectraMax Mini SpectraMax iD5 SpectraMax i3x (onboard) SpectraMax M5e The SpectraMax ® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. Do not use a dry plate. The SpectraMax 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications, especially DNA analysis. Where is the instrument serial number located? The serial number is on. Auction Details Bio + Laboratory Equipment Expo. 1. The multi-channel design truly mimics a dual-beam spectrophotometer. The patented multichannel optical design of the SpectraMax® 190. 0 nm full width half maximum. Molecular Dynamics Phosphorimager Model 425F + details. Moonrise and moonset. 13. 0) at 37 °C, fluorescence intensity was recorded on a Spectramax M5 Multimode plate reader. At indicated times, CellTiter 96 Aqueous One reagent was added to each well and absorbance was measured at 490 nm using SpectraMAX 190 (Molecular Devices). Temperature control and shaking come as standard. Patient samples were diluted 1:100, except for patients with CML for whom a dilution of 1:300 was used. The VersaMax and SpectraMax 190 read 96-well microplates. It measures the optical density (OD) of samples in 96-wellMolecular Devices Spectramax 190 Plate Reader used. SpectraMax Plus384, 190, 340PC384, and VersaMax Installation Guide Author: Molecular Devices Subject: Installation Guide Keywords: SpectraMax Versa and others Detection Platform Created Date:The Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. 384,340PC384,190,ABS,ABS Plus,VersaMax,FlexStation 3 0200-5060 SpectraTest FL1 FluorescenceValidation Plate0200-6262. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. The SPECTRAmax 340PC can mea- SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual 1-3 Introduction General Overview The SPECTRAmaxŽ 190 microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. Molecular Devices SpectraMax 340PC Microplate Spectrophotometer $ 3,500. The VersaMax and SpectraMax 190 read 96-well microplates. Molecular Dynamics Phosphorimager Model 425F + details. Plate chamber design of the SpectraMax category 1 microplate readers. Web Information The Spectramax 190 absorbance microplate reader utilizes a patented multichannel optical design to simulate a dual beam spectrophotometer to help eliminate errors through the usage of a dual fiber optic exposure. The temperature in the plate chamber is ambient and isothermal. The new SpectraMax 1000 from California Lightworks is an extremely powerful, feature packed vertical grow light for indoor horticulture. Get absorbance measurements from 190 to 1000 nm quickly for samples in test tubes, cuvettes, and 96- or 384-well microplates. SpectraMax® Paradigm® Multi-Mode Detection Platform. The iron contents were monitored at 562 nm using a microplate spectrophotometer (SPECTRAmax 190, Molecular Devices Corporation, USA). Perkin Elmer HTS 7000 Bio Assay ReaderSpectraMax® 190 absorbance plate reader enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. and planktonic cells, was measured at 595 nm in a spectrophotometer (SpectraMax 190, Molecular Devices, Sunnyvale, CA, USA). Narrow bandwidths deliver increased measurement accuracy and linearity over the widest range of assays, including. book Page 1 Wednesday, July 7, 2010 2:09 PMFig 2: Enzymatic response of synthetic compounds. Double-click the unknown device with the yellow warning icon. Molecular Devices SOFTmax PRO software is a highly integrated program that can be used to control and collect data from the SPECTRAmax 190. The final value was expressed as ng/g protein. SpectraMax ABS and SpectraMax ABS Plus Microplate Spectrophotometers User Guide Temperature Regulation When you power on the instrument the incubator is off. ; The top 3 importers of Spectramax are India with 365. TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate spectrophotometersproviderapidandsensitivemeasurementsofavarietyofanalytes. The change in absorbance was followed on either a Spectrmax 190 or Spectrmax Gemini XS plate reader (Molecular Devices Corp. Performance Specifications . Examples: fiPress carefully to engage,fl fiDo not press down. The SPECTRAmax 190 is equipped with an 8-pin DIN RS-232 serial port through which a computer can communicate with and control the instrument. Each sample has a discrete sample beam and reference. Robust, high-value microplate readers that can run samples. The plate. 119. When the user applies a set temperature of 37°C, the top is heated to 37. IMI detection was conducted using the Eurofins Imidacloprid ELISA kit (Eurofins Abraxis, Warminster, PA, USA) following the manufacturer’s instructions for extraction and quantification of IMI residues in leaf tissue and using a spectrophotometer (SpectraMax 190, Molecular Devices, San Jose, CA, USA). INTRODUCTION The SpectraMax M2 and SpectraMax M2e Multidetection Readers are monochromator based microplate readers that have 6well to 38 4well microplate reading capability as wellThe SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance and can be equipped to read volumes as low as 2uL in one multimode reader package. The SpectraMax Plus 384 reader is equipped with an innovation patented by Molecular Devices, the PathCheck® sensor, which measures the depth of a sample in a microplate by optical path length. The PathCheck sensor can extend the instrument linearity by a factor of three or more. SpectraMax L Microplate Reader is a sensitive luminometer with programmable injector options that measures flash and glow luminescence assays, including dual luciferase. We have 1 Molecular Devices SpectraMax 190 manual available for free PDF download: User Manual . For a complete list of the instruments supported by this release of the SoftMax Pro Software, see Supported Instruments on page 111. SpectraMax® Plus 384 microplate reader can run both standard spectrophotometer and microplate reader applications on the same instrument. Microplate Reader Shelf. Cell Apoptosis Assay Following treatment, the apoptosis rate of H9c2 cells was analyzed by flow cytometry analyses using the Annexin V-FITC/PI Cell Apoptosis Detection Kit (Dojindo. The control panel consists of a 2-x-20-character LCD and eleven pressure-sensitive membrane keys that can be used to control some functions of the instrument. SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual 1-3 Introduction General Overview The SPECTRAmaxŽ 190 microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. 9000-0756. to 500 nm) spectroscopy (SpectrMAX 190; Molecular Probes, Sunnyvale, CA, USA) after a 1-h reaction at room temperature. . Wavelength range 190 nm to 850 nm. Theseinstrumentsmeasuretheopticaldensity(OD)ofsamplesatselected wavelengthsinasinglereadmode. SoftMax Pro Software has been integrated by many leading robotics andThe VersaMax and SpectraMax 190 read 96-well microplates. The SpectraMax GEMINI EM uses two holographic diffraction grating monochromators which allow for individual optimization of wavelengths for both excitation and emission. Temperature control and shaking come as standard. Perkin Elmer HTS 7000 Bio Assay ReaderSpectraMax Plus or SpectraMax 190 and SoftMax Pro Software automatically: •Make A 260 and A 280 measurements •Measure the optical pathlength of each sample with the PathCheck sensor •Normalize the absorbance values to a 1 cm pathlength •Calculate concentrations •Make specialized calculations (e. Gemini™. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. The SpectraMax® 190 spectrophotometer is ideal for most life science applications, especially DNA analysis. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. TheSpectraMax®190MicroplateSpectrophotometer,SpectraMax®340PC384Microplate. 2 - 3. The drawing shows a standard microplate of 15 mm height covered with a lid. The SpectraMax ABS/ABS Plus Microplate Readers provide fast absorbance detection without the use of filters with monochromator-based wavelength selection for visible and. Step 2. 078 μg/mL), and the results were expressed as μg Fe (II)/g of extract. Molecular Dynamics Phosphorimager Model 425F + details. (volume is not critical because water does not absorb light appreciably between 190 and 900 nm) and read the plate. Photometric Performance SpectraMax 190 Item Description. The ABS reader ranges from 340–850 nm in wavelength and the ABS Plus reader ranges from 190–1000 nm, which is equivalent to having 510 or 810 free filters, respectively. SpectraMax Gemini EM & FLEXstation (bottom read) 1. Molecular Devices LLC 96 well microplate spectrophotometer spectramax 190 96 Well Microplate Spectrophotometer Spectramax 190, supplied by Molecular Devices LLC, used in various techniques. Description 1. Molecular Devices SpectraMax ABS Plus Microplate Reader; Related products. Capable of detecting DNA down to 25 ng per well, this model gives users the same. For more information, please visit us at 190 Absorbance Microplate Reader. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. As per Volza’s India Import data, Spectramax import shipments in India stood at 365, imported by 145 India Importers from 28 Suppliers. Molecular Devices provides the complete solution covering the instrument and software: • SpectraTest® ABS1, FL1, and LM1 Validation Plates for hardware validation of absorbance, fluorescence, and luminescence modes • IQ/OQ for all microplate readersSpectraMax® 190 absorbance plate reader enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. Perkin Elmer HTS 7000 Bio Assay ReaderFigure 1. This assay kit is optimized for the SpectraMax i3x Multimode Microplate Reader with a preconfigured protocol in SoftMax Pro Software for rapid. #3635 or Greiner cat. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Capable of detecting 25ng of DNA per well, this model provides users with the same sensitivity as conventional systems to produce precise nucleic acid measurements. The multi-channel design truly mimics a dual-beam spectrophotometer. SpectraMax 190 Absorbance Microplate Readerwith laptop and softwareEnables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. . Introduction. SpectraMax® 190 absorbance plate reader enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. (b) Fluorescence responses of probe HADP and control compounds 2–4 (each 5 µM) towards human heparanase (HPA) (1 µg) in 40 mM NaOAc buffer (pH 5. 312 gain calibration failed. ATP concentration (M) Average RLU SpectraMax L SpectraMax i3x (cartridge) SpectraMax Mini SpectraMax iD5 SpectraMax i3x (onboard) SpectraMax M5eThe SpectraMax ® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. Stray light. . The SpectraMax 340PC384 features correction for varying microplate well volumes and the elimination of standard curves based on PathCheck. The cell viability was normalised to the control group. • Last day to purchase a service plan for SpectraMax 190 Microplate Reader is December 31, 2027. 190 Gorge Road West has a Walk Score of 82 out of 100. The absorbance of the reaction mixture was recorded at 593 nm (SpectraMax 190, Molecular devices) after 5 min. By using PathCheck, SpectraMax readers can automatically normalize sample absorbance values to a 1-cm pathlength and calculate the concentrations. These models can no longer be repaired. Phone Number Login / Register. Example: [Drawer]. ®The SpectraMax Vertical 1000 uses only the highest-efficacy ams-Osram LEDs with efficiencies up to 4. HTRF is a proprietary time-resolved fluoresce nce technology that overcomesThe VersaMax and SpectraMax 190 read 96-well microplates. A four‐parameter logistic function was used to fit the curve and determine unknown concentrations with the software. 2. for every assay. The optical system of the SpectraMax 190 Microplate Reader is built around a monochromator, which allows for selection of up to six wavelengths at a time for absorbance detection in the UV-visible wavelength range (190 nm – 850 nm). All service plan coverage will end by December 31, 2028. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. spr * SpectraMax i3(x) SpectraTest ABS2 v1. ) Click the "OK" button on SoftMax Pro Setup dialog box . Perkin Elmer 1420 Victor 3V + details. Certified SpectraMax ® M5 e-HTRF Readers The SpectraMax M5 e reader has the same perfor mance specifications as the M5 but is certified for use with Cisbio Bioassays HTRF (Homogeneous Time-Resolved Fluorescence) technology. #655801; Quartz: Hellma cat. Labsystems Fluoroskan Ascent FL Microplate Fluorometer $ 3,250. SpectraMax 190 Absorbance Microplate Reader with laptop and software Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. The Spectramax 190 has an array of data collection modes, including kinetic, endpoint, and spectral scan modes. . The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-Tumor cells were plated onto 96-well plates (500 cells/well), and 10 µl of Premix WST-1 Cell Proliferation Assay System (Takara Bio Inc. This publication represents a sampling of scientific articlesSpectraMax 190 and Spect FRET fluorescence, top- le-Mode Detection Fluorescence Sir and bottom-read, cell-based assay, lal injection in both 96- and 384-well lates, excellent sensitivity, Autorinse range, du microp 0+ pre-defined protocols; lac compatible based (visible 405-750 nm)The change in absorbance was followed on either a Spectrmax 190 or Spectrmax Gemini XS plate reader (Molecular Devices Corp. . Perkin Elmer 1420 Victor 3V + details. The patented multichannel optical design of the SpectraMax® 190 Absorbance Microplate Reader mimics a dual beam spectrophotometer, measures each sample in the plate. Monochromator wavelength selection saves you the. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. 1649 Biochemical characterization of a novel high-affinity and specific plasma kallikrein inhibitor D Kolte1, JW Bryant2, D Holsworth2,JWang1, P Akbari1, GW Gibson2 and Z Shariat-Madar1 1Department of Pharmacology, School of Pharmacy, University of Mississippi, University, MS, USA, and. Temperature uniformity within the microplate may vary depending on the type of microplate used. Here, we demonstrate several different ways the ABS Plus reader, in combination with the SpectraDrop™ Micro-Volume Microplate and SoftMax® Pro Software, can quantitate double-stranded DNA and bovine serum albumin (BSA. . Molecular Devices technical support is available by phone and e-mail. Molecular Devices Spectramax 190 Absorbance Microplate Reader. Molecular Spectramax 190 Microplate Reader. The Gemini XPS Reader has dual monochromators that allow users to utilize new and novel dyes without purchasing expensive filter sets. $4,500. Superior flexibility SpectraMax® 190 Absorbance Plate Reader, Molecular Devices. Molecular Devices Spectramax 190 Plate Reader used. SpectraMax i3x reader measures absorbance, fluorescence, & luminescence with user-upgradeable application including western blot imaging, AlphaScreen, fast kinetics along with injectors plus additional detection modes. Not all manufacturers microplates are the same with regard to design, mate- rials, or conÞguration. Molecular Dynamics Phosphorimager Model 425F + details. Products : SpectraMax M2/M2e reader, SpectraMax M4 reader, SpectraMax M5/M5e reader, Gemini XPS reader, SpectraMax 190 reader, VersaMax reader, Gemini EM reader, SpectraMax Plus 384 reader. Perkin Elmer 1420 Victor 3V + details. Spleen cell proliferation was evaluated at different stages of the study and by different methodologies. Standard concentrations ranged from 1x10-11 M to 1x10-6 M. 0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. For planktonic growth, 120 μ L of the bacterial cultures from each well was transferred to well plate and the a new 96-6 optical density at 595 nm was measured. Find Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details at the best price available at Triad Scientific Call us at 732 292-1994 or 800 867-6690 | Email us at triadscientific@gmail. SpectraMax® 340PC384 Microplate Reader for acquiring data in endpoint, kinetic, and spectral scan modes using wavelegths from 340-850 nm, tunable in 1 nm increments. The Molecular Devices SpectraMax 384 Plus is a UV/Vis spectrophotometer and microplate reader combination for more reliable and fast data reporting with built-in cuvette port and microplate drawer. The resulting absorbance levels were then quantified spectroscopically at 560 nm using a SpectrMax® 190 spectrophotometer . Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. ¨The absorbance was measured by an enzyme-labeled instrument (SpectraMax 190, Shanghai, China) at 482 nm. 1) All parts of the SPECTRAmax 190 Microplate Spectrophotometer are warranted for a period of one (1) year from the original date of delivery. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. . Molecular Devices SpectraMax 340PC384 Microplate Reader $ 4,000. Database contains 2 Molecular Devices SpectraMax 190 Manuals (available for free online viewing or downloading in PDF): Operator's manual, Operation &. SOFTmax PRO. 1. The Solution Speaking about how OligoMaker uses the SpectraMax 190, Karl Ross-Petersen explains, "We use the SpectraMax 190 as an important step in testing the DNA/RNA. 00. For aqueous solutions, our patented* PathCheck® sensor. . spectramax i3x (Danaher Inc) Danaher Inc is a verified supplier. 0 out of 5 $ 9,995 $ 9,495. 5 mM −1 ∙cm −1) in a SpectraMax 190 plate reader (Molecular Devices). 303 unable to cal dark current. 305 reference level saturation. See More Information. Time style: am/pm AM/PM 24-hour. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. Molecular Devices SpectraMax 190 User Manual (55 pages) Microplate Spectrophotometers. ®plate reader for both 966 and 384 well plates and cuvette, spectral range 190-1000 nm, 2nm bandwidth. The SpectraDrop Microplate incorporates a specially designed adapter and a slide pair whose optical clarity allows measurements in absorbance and. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid- This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. 0 nm across. Molecular Devices SpectraMax 190 Microplate Reader is available from The Lab World Group. ZERO BIAS - scores, article reviews, protocol conditions and more. STAKMAX. Examples: “Press carefully to engage,” “ Do not press down. 118 Gemini XPS Fluorescence Microplate Reader . Home. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. For customers outside the U. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. (2012). The patented multichannel optical design. When connecting for the first time to either the SpectraMax L reader or StakMax system. ” SPECTRAmax 340PC Microplate Spectrophotometer Operator’s Manual 1-3 Introduction General Overview The SPECTRAmax ® 340PC incorporates a holographic grating monochromator which allows you to specify a precise wavelength, from 340 nm to 850 nm, for the absorbance maximum of your sample. See the installation guide or user guide. 02 at 750 nm using a spectrophotometer (SpectraMax®190; Molecular Devices, San Jose, CA, United States). The multi-channel design truly mimics a dual-beam spectrophotometer. 313 reference gain check fail. Molecular Devices SpectraDrop ™ Micro-Volume Microplate allows users to read up to 64 samples per plate on SpectraMax ® Microplate Readers, with sample volumes as low as 2 µL. The SpectraMax® Gemini™ EM Microplate Spectrofluorometer from Molecular Devices® provides a flexible environment to determine the optimal excitation and emission settings for most fluorescent intensity assays. $550. Introduction. Our Price: $6,995. 315 can't find zero order. Free shipping. Keywords: spectramax i3 multi-mode platform, spectramax i3, spectramax i3 system, scanlater western blot system, spectramax minimax imaging cytometer, softmax pro software,. The corrected absorbance is within 5% of the. Italic and boldface type are used for emphasis. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-SpectraMax M Series Multi-Mode Microplate Readers 7 The SpectraDrop Micro-Volume Microplate offers the ability to use as little as 2µL samples with 24- or 64-well plates. Microplate Readers Molecular Devices Spectramax iD3. The SpectraMax ABS readers use a grating monochromator to select the exact wavelength needed . D) units. Prior to the reading of each plate, the microplate reader was “blanked” with a. Wavelength Accuracy: < ± 2. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. The VersaMax and SpectraMax 190 read 96-well microplates. Seller InformationAnytimeLabTrader. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. 0 nm * Wavelength Repeatability ± 0. For aqueous solutions, our patented* PathCheck® sensor technology senses the depth of the liquid in each microplate well, and normalizes the absorbance value to a 1-cm pathlength. The SpectraMax ABS readers use a grating monochromator to select the exact wavelength needed .